Skip to content

Equipment

Cleaver-Brooks CBEX Firetube Boiler

  • Steam up to 300 psig
  • Hot water up to 125 psig
  • 100 to 2,500 HP
  • 2 Pass and 3 Pass
  • Natural gas/propane, #2 light oil, combination
  • Waterback or Dryback design
  • Offers 30 ppm NOx with 3% O2 across the 10:1 turndown range
  • Sub 5 ppm NOx without SCR available on most models
  • Meets 10 ppm CO requirement
  • 3 pass model includes an option for an integral pre-piped feedwater economizer

Cleaver-Brooks FLX Flexible Watertube Boiler

  • 1,500-25,000 MBH Input
  • Natural Gas, #2 Light Oil, Propane, Digester Gas
  • 15-250 psig Design Pressure
  • Available to <9 ppm NOx
  • Field Erectable

Cleaver-Brooks Model 5 Watertube Boiler

  • Steam or hot water
  • 1.5 to 8.0 MBTU
  • Natural gas, #2 oil, propane
  • 15 to 500 psig (special to 675 psig) on steam
  • 140 psig on hot water standard with option to 450 psig @ 410F

Cleaver-Brooks CBLE Firetube Boiler

  • Steam up to 300 psig
  • Hot water up to 125 psig
  • 50 to 800 HP
  • 4 Pass
  • Natural gas/propane, #2 and #6 oil, combination
  • Alternate fuel capability
  • Waterback or Dryback design
  • 60 ppm, 30 ppm, 9 ppm and 5 ppm NOx emission rates are available

Cleaver-Brooks CBJT Firetube Boiler

  • Steam up to 300 psig
  • Hot water up to 125 psig
  • 50 to 1,600 HP
  • 2, 3 and 4 Pass
  • Natural gas/propane, #2 light oil, #6 oil or combination
  • Dryback or Waterback design
  • Available to < 30 ppm NOx emissions on 2 & 3 pass models
  • Available to <9 ppm NOx emissions on 4 pass models

Cleaver-Brooks ICB Firetube Boiler

  • Steam and hot water
  • 3-pass integrated package
  • 100 to 800 HP
  • Natural gas, #2 and #6 oil, combination
  • 15 to 250+ psig on steam
  • 30 to 125 psig on hot water
  • Available to <30 ppm NOx

Cleaver-Brooks D-Style Industrial Boiler

  • Steam, temperatures to 1,050°F
  • 10,000 to 500,000 lb/hr
  • Natural Gas, #2 and #6 oil, refinery fuels, alternative fuels, combination
  • Design pressure up to 1,800 psig
  • Available to less than 5ppm NOx, Ultra-Low CO

COMPACT® Semi-Instantaneous Indirect Water Heaters

  • High-quality design and construction
  • Complete package with only four piping connections
  • High-capacity output
  • ANTICIPATOR® temperature control regulates hot water outlet temperatures ±4F
  • Copper-nickel shell, naval brass tubesheet, and optional copper (copper nickel) preclude rusty water
  • Double solenoid temperature-limit system prevents overheated water from entering the distribution system
  • Meets seismic Zone 4 requirements
  • Built to ASME standards; meets code requirements, Meets BOCA and IAPMO code requirements
  • Available in steam to hot water and hot water to hot water configuration

Cleaver-Brooks Model LVR Electric Boiler

  • Electrical Hydronic Boiler
  • 90 to 540 kW, up to 335 – 1850 MBTu
  • 480 – 600V
  • 160 psig
  • Zero-emissions
Medium Voltage Electric Boler

Cleaver-Brooks Model MVR Medium Voltage Boiler

    • Medium voltage (4,160 V)
    • Input power: 1.67 MW to 12 MW
    • Hot water capacity: 5,698 to 40,945 MBH
    • Hot water design pressure: 160 psig (ASME Section IV)
    • Steam capacity: 5,873 to 42,199 lb/hr (From and at 212°F)
    • Steam design pressure: 150 or 250 psig (ASME Section I)